Reflow Wingman Crossing Catheter
Compatible with the physician’s choice of guidewire. Works with the Reflow Spex™ and SpexLP™ catheters for added support in lesion crossing.
REQUEST A QUOTEInstructions For Use
Indications, Safety, & Warnings
CAUTION: This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Adverse Events, and Procedural Steps.
Intended Use
The Wingman Crossing Catheter is intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices, and provide a conduit for delivery of saline solutions or diagnostic contrast.
Indications for Use
The Wingman Crossing Catheter is intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices, and provide a conduit for delivery of saline solutions or diagnostic contrast.
Contraindications
The Wingman Crossing Catheter is contraindicated for use in the coronary and cerebral vasculature.
Warnings
Wingman:
Hydrophilic wires prone to excessive swelling (e.g. ZipWire) should not be used with the Wingman Crossing Catheter.
Single Use only. Do not reuse/resterilize. Reusing the device could result in compromised device performance, cross-infection and other safety related hazards.
Do not use if device is open or packaging is damaged
Never advance, withdraw or rotate an intravascular device against resistance until the cause is determined by fluoroscopy.
This device contains nickel and should not be used in patients with known allergies to nickel.
Wingman 14C:
Hydrophilic wires prone to excessive swelling (e.g. ZipWire) should not be used with the Wingman Crossing Catheter.
Single Use only. Do not reuse/resterilize. Reusing the device could result in compromised device performance, cross-infection and other safety related hazards.
Do not use if device is open or packaging is damaged
Never advance, withdraw or rotate an intravascular device against resistance until the cause is determined by fluoroscopy.
Precautions
Store in a cool, dry place. Protect from direct sunlight and high temperature.
Use only appropriately sized ancillary device, as shown in the Specifications below.
Maximum Infusion Pressure: 360 psi (2482 kpa)
Use the catheter prior to the “Use By” date specified on the package
The catheter should only be used by physicians qualified to perform percutaneous, vascular interventions.
Precautions to prevent or reduce clotting should be taken when any catheter is used in the vascular system. Use of systemic heparinization and heparinized saline solution should be considered.
Exercise care while handling the catheter during procedure to reduce the possibly of accidental damage, kinking or bending.
Manipulation of the catheter should only occur under fluoroscopy.
©2024 Reflow Medical, Inc. All rights reserved. Reflow Medical, Wingman and The Pulse of Medical Ingenuity are registered trademarks or trademarks of Reflow Medical, Inc. This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Adverse Events, and Procedural Steps.